Manufacturer: Sun International Co., Ltd., Japan   |   Authorized Distributor in India: Akira Analytical Solutions Pvt. Ltd.
HiQ Sil chromatography columns

HiQ Sil Columns

Japanese silica technology · Indian technical support

C8 stationary phase

HiQ Sil C8-10

Lower-pressure C8 selectivity for conventional analytical separations.

Particle size: 10 µmPore size: 120 ÅAnalytical HPLC

Request QuoteTechnical Guidance

HiQ Sil C8-10 HPLC column family

Overview and typical use

HiQ Sil C8-10 uses a C8 stationary phase. Lower-pressure C8 selectivity for conventional analytical separations. The phase should be selected after considering analyte polarity, ionization, aromaticity and the selectivity needed to resolve critical pairs. Method suitability must be confirmed experimentally.

Operating guidance

Use HPLC-grade solvents, filter samples where appropriate and avoid abrupt changes between immiscible mobile phases. Introduce flow gradually, monitor pressure and allow complete equilibration before evaluating retention. Remove non-volatile buffers before storage. Avoid exceeding the limits stated in the manufacturer’s documentation.

Typical applications

Potential uses include pharmaceutical assay and impurity methods, chemical purity testing, food-related analysis, environmental research, natural-product profiling and academic method development, provided the analytes and mobile phase are compatible with the phase.

Analytical column specifications

Part NumberColumn DimensionParticle SizePore SizePhase
B46-035-10-1204.6 mm × 35 mm10 µm120 ÅC8
B46-050-10-1204.6 mm × 50 mm10 µm120 ÅC8
B46-075-10-1204.6 mm × 75 mm10 µm120 ÅC8
B40-100-10-1204.0 mm × 100 mm10 µm120 ÅC8
B046-100-03-1204.6 mm × 100 mm10 µm120 ÅC8
B40-150-10-1204.0 mm × 150 mm10 µm120 ÅC8
B46-150-10-1204.6 mm × 150 mm10 µm120 ÅC8
B40-250-10-1204.0 mm × 250 mm10 µm120 ÅC8
B46-250-10-1204.6 mm × 250 mm10 µm120 ÅC8
B40-300-10-1204.0 mm × 300 mm10 µm120 ÅC8

Guard cartridges

Part NumberDimensionPack
B040-010-10-120-CG4.0 mm ID × 10 mm LSingle cartridge
B046-010-10-120-CG4.6 mm ID × 10 mm LSingle cartridge
B040-010-10-120-10-CG4.0 mm ID × 10 mm LPack of 5
B046-010-10-120-10-CG4.6 mm ID × 10 mm LPack of 5

Cartridge guard columns require a compatible guard-column adaptor. Confirm part-number compatibility before ordering.

Frequently asked questions

What is HiQ Sil C8-10?

HiQ Sil C8-10 is a C8 silica-based HPLC column family with 10 µm particles and a listed pore size of 120 Å.

What is its main separation mode?

Its primary use follows the chemistry of the bonded phase. Reversed-phase products use aqueous-organic mobile phases, while polar and bare-silica phases may be used in normal-phase or other validated modes.

Which dimensions are available?

The catalogue lists multiple 4.0 mm and 4.6 mm internal-diameter analytical columns in lengths from 35 mm to 300 mm, depending on the part number.

Are guard columns available?

Yes. Matching cartridge guard columns are listed, and a compatible guard-column adaptor is required.

Are prices shown online?

No. Contact Akira Analytical Solutions for a quotation and availability.

How should the column be conditioned?

Condition gradually with a fully compatible mobile phase until pressure and detector baseline are stable.

How should it be stored?

Flush out buffers and salts, use a compatible storage solvent and cap both ends to prevent drying or contamination.

How can I obtain technical support?

Send the analyte, mobile phase, instrument, current column and desired separation details to sales@akiralabs.com.